Pivot Hydraulic Sizer
Centre-pivot flow, span hydraulics, pump duty, capital cost and economic mainline sizing.
From peak crop water demand to design flow, total dynamic head and motor kW — a worked example in metric and imperial units.
An undersized pump leaves the crop short of water in the hottest week of the season; an oversized one wastes capital and energy for twenty years. Sizing a pump for a centre pivot (called a center pivot in North America) comes down to two numbers — flow and total dynamic head — and both follow from the crop, the machine and the site. This guide walks through the method with a worked example of an eight-span pivot of about 500 m (1,640 ft).
The pivot must replace what the crop uses in the peak period, after allowing for application losses and the hours the machine can actually run. You need three inputs:
The irrigated area of a full circle is π × R². With a machine length of 500 m, the area is 78.5 ha (194 acres). The gross depth needed per day is ETc ÷ efficiency, and the flow follows from the area and running hours:
Dividing flow by area gives the system capacity: 330 m³/h is 91.7 L/s, or 1.17 L/s/ha (about 7.5 gpm per acre). Most pivots fall between 0.6 and 1.3 L/s/ha (roughly 4–8.5 gpm/acre). Above that, pump and pipe costs climb quickly; below it, the system is likely to fall behind in a heatwave.
The sprinkler package needs a minimum pressure at the outer end of the machine. To get it there, the pivot point must supply that pressure plus the friction loss along the spans plus any rise in ground level to the highest point the machine reaches.
Span friction is calculated span by span with the Hazen-Williams equation, using the flow still travelling through each span (flow falls towards the outer end as sprinklers discharge it). A C-value of around 130 suits galvanised span pipe. If span friction is more than about 40% of the pivot-point pressure, larger span pipe is usually worth pricing.
Total dynamic head (TDH) is everything the pump has to lift and push against:
In the example the mainline is 800 m of 300 mm internal diameter pipe, giving a velocity of about 1.3 m/s — comfortably below the 1.5–2.0 m/s at which friction and surge risk start to bite. Static lift should come from a proper pumping test and allow for seasonal drawdown: in a borehole supply it is often the most uncertain number in the calculation.
Select the motor at the next standard frame size above the input power, and choose the pump so that the duty point (330 m³/h at 64 m) sits close to its best-efficiency point — not at the edge of its curve.
A smaller mainline is cheaper to buy but costs more to pump through every season. Compare the life-cycle cost of each standard diameter — pipe capital plus the present value of energy over the system's life — and the optimum is often one size larger than the cheapest pipe that works. The same logic applies to the power source: diesel, grid and solar-hybrid pumping have very different capital and running cost profiles.
We advise investors, lenders and developers on irrigation, investment cases and due diligence.
Talk to usCentre-pivot flow, span hydraulics, pump duty, capital cost and economic mainline sizing.
FAO-56 reference ET₀, crop water use, daily soil-water balance with stress, irrigation schedule, yield response and water economics.
Life-cycle cost, levelised cost of water, carbon and payback for diesel, grid and solar-hybrid pumping.
Soils, water, climate, logistics and tenure — the thirteen criteria we use to screen irrigated farmland, with deal-breakers and weighting.
Read the guide →How Penman-Monteith ET₀, crop coefficients and a soil-water balance turn weather data into a practical irrigation schedule.
Read the guide →